Compare Description Drawings, CAD & Specs Avail. Price
5000W-LP2-50 Long Pulse 5000W Water-Cooled Ø50mm Thermal Sensor7Z071355000W-LP2-50Thermal Laser Power Sensor, LP2 Type, 20-5000 W, Ø50 mm, 350-2200 nm, Water-Cooled

Specifications

  • Product Name
    5000W-LP2-50
  • Absorber Type
    LP2 - Long pulse and CW high damage threshold
  • Aperture Size
    Ø50 mm
  • Spectral Range
    350 to 2200 nm
  • Minimum Power
    20 W
  • Maximum Average Power
    5000 W
  • Response Time
    3 s
  • Maximum Average Power Density
    2.5 kW/cm²
  • Maximum Energy Density <100 ns
    0.1 J/cm²
  • Maximum Energy Density 2 ms
    130 J/cm²
  • Cooling
    Water
  • Dimensions
    Ø146 x 47mm
  • Cable Length
    1.5 m
  • CE Compliance
    Yes
  • UKCA Compliance
    Yes
  • China RoHS Compliance
    Yes

Features

LP2 Sensors Coating With Very High Damage Threshold and Very Low Reflection

Even higher damage threshold…flat spectral response…absorption up to 96%... These are some of the characteristics of the new “LP2” type laser power sensors from Ophir.

Water Cooled Sensors: Things to Look Out For

Water cooled sensors are commonly used when measuring laser beams of more than a few hundred watts. In this video, you will learn about some critical issues you need to consider when using water cooling, such as water temperature, water flow rate, and corrosion prevention.

Choosing a Thermal Sensor

In this short “Basics” video we review the use – and selection - of thermal sensors for measuring low, medium and high laser powers.

Sensors for Measuring Laser Power

In this short "Basics" video we review in general how one goes about measuring laser beam power, so that you'll have a clear understanding of what the different sensor types are, and when to use each type.

Thermal Power Sensor Accuracy

Ophir former CTO Dr. Ephraim Greenfield discusses the various factors that contribute to uncertainties in measurement when using Ophir laser power and energy meters.

Effects of Incidence Angle on Measurements

In this video, you will learn to what degree a beam’s incidence angle matters, and for which sensor types this should be taken into account.

Thermal Sensor Calibration

As the spectral sensitivity of the absorber used for the power and energy measurement is not fully linear, Ophir sensors get a high precision calibration by default with more than one wavelength.

Each thermal sensor is calibrated independently of a particular Ophir power meter with its calibration information contained in the DB15 plug. When the sensor is connected to the meter, the meter reads and interprets this information to display a calibrated reading. Each power meter is calibrated independently and has the same sensitivity as an other meter within about 2 tenths of a percent.

Unless otherwise indicated, Ophir sensors and meters should be recalibrated within 18 months after initial purchase, and then once a year after that.

Absorption of different thermal sensor absorber types

Frequently Asked Questions

Accessories

5000W / 10K-W / 15K-W Protective Housing

Protective Housing with shutter for Ophir 5000W, 10K-W and 15K-W sensors.

Compare Description Drawings, CAD & Specs Avail. Price
7Z08344Protective Housing and Shutter, 5000W / 10K-W / 15K-W Sensors
$3,162

10K-W Protective Cover for Water Cooled Sensors

Protective Cover with Target Pattern for 1000W, L1500W, 5000W, 10K-W and 15K-W sensors (1 unit supplied with 5000W, 10K-W, and 15K-W).

Compare Description Drawings, CAD & Specs Avail. Price
1G01332Protective Cover, 15K-W, 10K-W, 5000W, L1500W, 1000W Sensors
$45

Metric Water Fitting

Metric water fittings for all water cooled sensors except 16K-W & 30K-W with quick connection to 10mm plastic tubing. The Metric water fittings are also suitable for the QBH Adapters. Replaces standard fitting connecting to 3/8" tubing (set of 2 each).

Compare Description Drawings, CAD & Specs Avail. Price
7Z08353Metric Water Connector, 10 mm, Water Cooled Sensors
$29

Fiber Adapters

This fiber adapter is used for mounting fibers with QBH termination to high power sensors L1500W-BB-50, L1500W-LP2-50, 5000W-BB-50 and 5000W-LP2-50. Suitable for beams with small or large divergence angles.

Compare Description Drawings, CAD & Specs Avail. Price
7Z08348QBH-L Fiber Adapter, Ø146 x 223 mm, High Power Sensors$3,662
7Z08349QBH-S Fiber Adapter, Ø146 x 177 mm, High Power Sensors$3,598

Thermal Sensor Cables

Order a cable of a different length along with the sensor to receive a cable other than the standard 1.5 m length.

Compare Description Drawings, CAD & Specs Avail. Price
7E01122AThermal Sensor Cable, 3 m Length, Connect to Power Meter$112
7E01122BThermal Sensor Cable, 5 m Length, Connect to Power Meter$112
7E01122CThermal Sensor Cable, 10 m Length, Connect to Power Meter$167
7E01122DThermal Sensor Cable, 12 m Length, Connect to Power Meter$167

Sensor Connector to BNC Adapter

The SH to BNC Adapter allows the connection of an Ophir sensor to a current or voltage measuring device for measurement of the raw sensor analog output. A current meter should be used for photodiode sensors. Current or voltage meters can be used for thermal sensors.

Compare Description Drawings, CAD & Specs Avail. Price
7Z11010BNC Adapter, DB15 Optical Sensor Connector
$92

Extended Warranty for Sensor

Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.

Compare Description Drawings, CAD & Specs Avail. Price
XWAR-SENSORExtended Warranty for Sensor$475