Compare Description Drawings, CAD & Specs Avail. Price
30K-W-BB-74 Broadband 30kW Water-Cooled Ø74mm Thermal Sensor7Z0713630K-W-BB-74Thermal Laser Power Sensor, BB Type, 0.1-30 kW, Ø74 mm, 800-2000 nm, Water-Cooled

Specifications

  • Product Name
    30K-W-BB-74
  • Absorber Type
    BB - Broadband general purpose
  • Aperture Size
    Ø74 mm
  • Spectral Range
    800 to 2000 nm
  • Minimum Power
    100 W
  • Maximum Average Power
    30 kW
  • Backscattered Power
    ~4.3% without Scatter Shield
    ~1.3% with Scatter Shield
  • Response Time
    7 s
  • Maximum Average Power Density
    10 kW/cm²
  • Cooling
    Water
  • Dimensions
    Ø229 x 100 mm
  • Cable Length
    10 m
  • CE Compliance
    Yes
  • UKCA Compliance
    Yes
  • China RoHS Compliance
    Yes

Features

Scatter Shields: Reducing Back-Reflected Power from High Power Sensors

When measuring very high power laser beams, even the few percent of the beam normally back-scattered from the sensor can be a problem. Ophir now offers Scatter Shields as accessories for our high power laser sensors. These can be mounted on the front flange of the sensors to reduce the backscatter by about 70%.

Sensors for Measuring Laser Power

In this short "Basics" video we review in general how one goes about measuring laser beam power, so that you'll have a clear understanding of what the different sensor types are, and when to use each type.

Measuring Ultra High Power Laser Beams

Laser beams with powers of many tens of Kilowatts are becoming more and more common in today's applications, industrial as well as research. This video will discuss the technical challenges in measuring such lasers, and will show you a range of solutions now available from Ophir for measuring up to 100KW -- safely, and accurately.

Water Cooled Sensors: Things to Look Out For

Water cooled sensors are commonly used when measuring laser beams of more than a few hundred watts. In this video, you will learn about some critical issues you need to consider when using water cooling, such as water temperature, water flow rate, and corrosion prevention.

Thermal Sensor Calibration

As the spectral sensitivity of the absorber used for the power and energy measurement is not fully linear, Ophir sensors get a high precision calibration by default with more than one wavelength.

Each thermal sensor is calibrated independently of a particular Ophir power meter with its calibration information contained in the DB15 plug. When the sensor is connected to the meter, the meter reads and interprets this information to display a calibrated reading. Each power meter is calibrated independently and has the same sensitivity as an other meter within about 2 tenths of a percent.

Unless otherwise indicated, Ophir sensors and meters should be recalibrated within 18 months after initial purchase, and then once a year after that.

Absorption of different thermal sensor absorber types

Frequently Asked Questions

Accessories

30K-W Scatter Shield Assy

Scatter Shield for mounting on front flange of 30K-W sensors to reduce backscattered power ('30K-W Scatter Shield Protective Cover (P/N 7Z08346)' is supplied with the Scatter Shield).

Compare Description Drawings, CAD & Specs Avail. Price
7Z08293Scatter Shield, 30K-W Sensors
$542
7Z08346Protective Cover, 30K-W Sensor with Scatter Shield$184

30K-W Protective Cover

Protective Cover with Target Pattern for 30K-W sensors (1 unit supplied with 30K-W sensors).

Compare Description Drawings, CAD & Specs Avail. Price
1G02406Protective Cover, 30K-W Sensors
$151

30K-W Rubber Feet Assembly

Rubber feet kit accessory for 30K-W sensor, recommended for use when the sensor is used with a vertical beam.

Compare Description Drawings, CAD & Specs Avail. Price
7Z0821730K-W Rubber Feet Assembly
$20

Metric water fittings for 20K-W & 30K-W

Metric water fittings for 20K-W & 30K-W for quick connection to 12mm plastic tubing. Replaces standard fitting connecting to 1/2" tubing (set of 2 each).
Note: the water connector is compatible also with the 16K-W-BB-55 sensor P/N 7Z07131

Compare Description Drawings, CAD & Specs Avail. Price
7Z08352Metric Water Connector, 12 mm, 20K-W / 30K-W Water Cooled Sensors
$48

Sensor Connector to BNC Adapter

The SH to BNC Adapter allows the connection of an Ophir sensor to a current or voltage measuring device for measurement of the raw sensor analog output. A current meter should be used for photodiode sensors. Current or voltage meters can be used for thermal sensors.

Compare Description Drawings, CAD & Specs Avail. Price
7Z11010BNC Adapter, DB15 Optical Sensor Connector
$92

Extended Warranty for Sensor

Customers that purchase the above items also consider the following items. Ophir-Spiricon meters and sensors include a standard manufacturers warranty for one year. Add a one year Extended Warranty to your meter or sensor, which includes one recalibration.

Compare Description Drawings, CAD & Specs Avail. Price
XWAR-SENSORExtended Warranty for Sensor$475